Vue de la page 3
4
SPECIFICATIONS
Dimensions: HH 352 B/W
Length 572 mm
Width 502 mm
Height 49 mm
Cut Out dimensions
Length 560 mm
Width 490 mm
Voltage 240 V ~ 50 Hz
Total Power 5.9 kW
1. Heat Zone 180 mm 1800 W
(halogen)
2. Heat Zone 145 mm 1200 W
(single circuit)
3. Heat Zone 120/180 mm 1700 W
(double circuit)
4. Heat Zone 145 mm 1200 W
(halogen)
5. Residual Heat Indicator
Rating plates:
INSTALLATION
Typ 083.0 HH 352 B Prod.No. 941 689 288
Instr. No. Ser.No. 5.9 kW
TRICITY BENDIX
240 V ~ 50 Hz
SWISS MADE
Typ 083.0 HH 352 W Prod.No. 941 689 289
Instr. No. Ser.No. 5.9 kW
TRICITY BENDIX
240 V ~ 50 Hz
SWISS MADE
23
154
H
H
Fig.1Unpacking
Please examine the appliance for any damage sustained
during transportation!
If the appliance is damaged please inform the installer or
retailer immediately, before the appliance is connec-ted.
The packing material should be disposed of properly.
Before using your hob
Clean your ceramic hob thoroughly before its first use.
Ceramic hobs are treated and cleaned the same way as
glass. When you use the ceramic hob for the first time
it can give off a smell for a short time as the manufacturing
deposits burn off.
This Tricity Bendix hob may be installed into any kitchen
worktop with a depth of 600 mm or more. The worktop
must be constructed of material resistant to 100°C.
The cut out in the worktop should be to the dimensions
shown in fig.1. Before making the cut out ensure that the
edges of the hob, that are to be adjacent to either a side
or rear wall, have a minimum distance of 55 mm between
the edge of the hob and the wall (fig.5).